7. HOW TO USE THE POINT TABLE
7 - 20
(c) Varying-speed operation
By setting the auxiliary function of the point table, the servo motor speed during positioning can be
changed. Point tables are used by the number of the set speed.
1) Absolute value command method ([Pr. PT01] = _ _ _ 0)
Set "1" or "3" to the auxiliary function to execute the positioning at the speed set in the following
point table.
At this time, the position data selected at start is enabled, and the acceleration/deceleration time
constant set in the next and subsequent point tables is disabled.
By setting "1" or "3" to auxiliary functions until point table No. 254, the operation can be
performed at maximum 255 speeds.
Be sure to set "0" or "2" to the auxiliary function of the last point table.
To perform varying-speed operation, be sure to set "0" to the dwell.
Setting "1" or more enables the automatic continuous positioning operation.
The following table shows an example of setting.
Point table No.
Dwell [ms]
(Note 1)
Auxiliary function
Varying-speed operation
1
0
1
Consecutive point table data
2
0
3
3
Disabled
0 (Note 2)
4
0
3
Consecutive point table data
5
0
1
6
Disabled
2 (Note 2)
Note 1. Be sure to set "0".
2. Be sure to set "0" or "2" to the auxiliary function of the last point table of the
consecutive point tables.
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...