4. PARAMETERS
4 - 4
4.1.3 Extension setting parameters ([Pr. PC_ _ ])
POINT
In the positioning mode, the following parameter cannot be used.
[Pr. PC04 Torque command time constant]
[Pr. PC09 Internal speed command 5/Internal speed limit 5]
[Pr. PC10 Internal speed command 6/Internal speed limit 6]
[Pr. PC11 Internal speed command 7/Internal speed limit 7]
[Pr. PC12 Analog speed command - Maximum speed/Analog speed limit -
Maximum speed]
[Pr. PC13 Analog torque command maximum output]
[Pr. PC23 Function selection C-2]
[Pr. PC32 Command input pulse multiplication numerator 2]
[Pr. PC33 Command input pulse multiplication numerator 3]
[Pr. PC34 Command input pulse multiplication numerator 4]
No.
Symbol
Name
Initial
value
Unit
Detailed
explanation
PC01
STA
JOG operation acceleration time constant
0
[ms]
Section 4.2.2
Acceleration time constant 1
0
[ms]
PC02
STB
JOG operation deceleration time constant
0
[ms]
Deceleration time constant 1
0
[ms]
PC03
STC
S-pattern acceleration/deceleration time constant
0
[ms]
PC04
TQC
Torque command time constant
0
[ms]
MR-JE-_C
PC05
SC1
Automatic operation speed 1
100.00
[r/min]
Section 4.2.2
PC06
SC2
Automatic operation speed 2
500.00
[r/min]
PC07
SC3
Manual operation speed 1
1000.00
[r/min]
PC08
SC4
Manual operation speed 2
200.00
[r/min]
PC09
SC5
Internal speed command 5
300.00
[r/min]
MR-JE-_C
Internal speed limit 5
PC10
SC6
Internal speed command 6
500.00
[r/min]
Internal speed limit 6
PC11
SC7
Internal speed command 7
800.00
[r/min]
Internal speed limit 7
PC12
VCM
Analog speed command - Maximum speed
0.00
[r/min]
Analog speed limit - Maximum speed
PC13
TLC
Analog torque command maximum output
100.0
[%]
PC14
For manufacturer setting
0000h
PC15
0000h
PC16
MBR
Electromagnetic brake sequence output
0
[ms]
MR-JE-_C
PC17
ZSP
Zero speed
50
[r/min]
PC18
*BPS
Alarm history clear
0000h
PC19
*ENRS Encoder output pulse selection
0000h
PC20
For manufacturer setting
0
PC21
0000h
PC22
*COP1 Function selection C-1
0020h
MR-JE-_C
PC23
*COP2 Function selection C-2
0000h
PC24
*COP3 Function selection C-3
0000h
PC25
*COP4 Function selection C-4
0000h
Section 4.2.2
PC26
*COP5 Function selection C-5
0000h
MR-JE-_C
PC27
*COP6 Function selection C-6
0000h
PC28
For manufacturer setting
0000h
PC29
*COP8 Function selection C-8
0120h
Section 4.2.2
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...