3. SIGNALS AND WIRING
3 - 60
(3) Pulse train input interface DI-2
Give a pulse train signal in the open-collector type.
1) Interface
Maximum input pulse
frequency 200 kpulses/s
Approximately
1.2 k
Ω
Servo amplifier
PP2
PG
V
CES
≤
1.0 V
I
CEO
≤
(Note)
Approximately
20 mA
Approximately
20 mA
(Note)
Approximately
1.2 k
Ω
NP2
SD
NG
V
CES
≤
1.0 V
I
CEO
≤
24 V DC ± 10%
300 mA
Note. Pulse train input interface is comprised of a photocoupler.
If a resistor is connected to the pulse train signal line, it may malfunction due to
reduction in current.
2) Input pulse condition
0.9
0.1
tc
tLH
tc
tHL
tF
PP2
NP2
tLH = tHL < 0.2 µs
tc > 2 µs
tF > 3 µs