3. SIGNALS AND WIRING
3 - 26
Device Symbol
Connector
pin No.
Function and application
I/O
division
Control
mode
P S T
Proportion
control
PC
Turn PC on to switch the speed amplifier from the proportional integral type
to the proportional type.
If the servo motor at a stop is rotated even one pulse due to any external
factor, it generates torque to compensate for a position shift. When the
servo motor shaft is to be locked mechanically after positioning completion
(stop), switching on the PC (Proportion control) upon positioning
completion will suppress the unnecessary torque generated to compensate
for a position shift.
When the shaft is to be locked for a long time, switch on the PC
(Proportion control) and TL (External torque limit selection) at the same
time to make the torque less than the rated by TLA (Analog torque limit).
Do not use PC (Proportional control) in the torque control. When PC
(Proportional control) is used in the torque control, operation may be
performed at a speed exceeding the speed limit value.
DI-1
Clear
CR
CN1-41 Turn CR on to clear the position control counter droop pulses on its leading
edge. The pulse width should be 10 ms or longer.
The delay amount set in [Pr. PB03 Position command
acceleration/deceleration time constant] is also cleared. When "_ _ _ 1" is
set to [Pr. PD32], the pulses are always cleared while CR is on.
DI-1
Electronic gear
selection 1
CM1
The combination of CM1 and CM2 enables you to select four different
electronic gear numerators set in the parameters.
DI-1
(Note) Input device
Electronic gear numerator
CM2
CM1
0
0
Pr.
PA06
Electronic gear
selection 2
CM2
0 1
Pr.
PC32 DI-1
1
0 Pr.
PC33
1
1
Pr.
PC34
Note. 0: Off
1: On
Gain switching
CDP
Turn on CDP to use the values of [Pr. PB29] to [Pr. PB36] and [Pr. PB56]
to [Pr. PB60] as the load to motor inertia ratio and gain values.
DI-1
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...