5. PARAMETERS
5 - 21
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control mode
P S T
PB17
NHF
Shaft
resonance
suppression
filter
Set the shaft resonance suppression filter.
Use this filter to suppress a low-frequency machine vibration.
When you select "Automatic setting (_ _ _ 0)" of "Shaft resonance suppression filter selection" in [Pr. PB23], the value
will be calculated automatically from the servo motor you use and load to motor inertia ratio. When "Manual setting (_
_ _ 1)" is selected, the setting written to the parameter is used.
When "Shaft resonance suppression filter selection" is "Disabled (_ _ _ 2)" in [Pr. PB23], the setting value of this
parameter will be disabled.
When you select "Enabled (_ _ _ 1)" of "Machine resonance suppression filter 4 selection" in [Pr. PB49], the shaft
resonance suppression filter is not available.
_ _ x x Shaft resonance suppression filter setting frequency selection
Refer to table 5.5 for settings.
Set the value closest to the frequency you need.
00h
_ x _ _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
x _ _ _ For manufacturer setting
0h
Table 5.5 Shaft resonance suppression filter
setting frequency selection
Setting
value
Frequency [Hz]
Setting
value
Frequency [Hz]
_ _ 0 0
Disabled
_ _ 1 0
562
_ _ 0 1
Disabled
_ _ 1 1
529
_ _ 0 2
4500
_ _ 1 2
500
_ _ 0 3
3000
_ _ 1 3
473
_ _ 0 4
2250
_ _ 1 4
450
_ _ 0 5
1800
_ _ 1 5
428
_ _ 0 6
1500
_ _ 1 6
409
_ _ 0 7
1285
_ _ 1 7
391
_ _ 0 8
1125
_ _ 1 8
375
_ _ 0 9
1000
_ _ 1 9
360
_ _ 0 A
900
_ _ 1 A
346
_ _ 0 B
818
_ _ 1 B
333
_ _ 0 C
750
_ _ 1 C
321
_ _ 0 D
692
_ _ 1 D
310
_ _ 0 E
642
_ _ 1 E
300
_ _ 0 F
600
_ _ 1 F
290
PB18
LPF
Low-pass
filter setting
Set the low-pass filter.
The following shows a relation of a required parameter to this parameter.
Setting range: 100 to 18000
3141
[rad/s]
[Pr. PB23]
[Pr. PB18]
_ _ 0 _ (Initial value) Automatic setting
_ _ 1 _
Setting value
enabled
_ _ 2 _
Setting value
disabled
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...