8. TROUBLESHOOTING
8 - 4
No. Name
Detail
No.
Detail name
Stop
method
(Note 2,
3)
Alarm
deactivation
Alarm code
Alarm
reset
Power
cycling
ACD2
(Bit 2)
ACD1
(Bit 1)
ACD0
(Bit 0)
Alarm
36
SSCNET receive error
2
36.1
Continuous communication data
error
SD
37.1 Parameter setting range error
DB
37
Parameter error
37.2 Parameter combination error
DB
0 0 0
37.3 Point table setting error
DB
39 Program
error
39.1 Program
error
DB
39.2 Instruction argument external error
DB
39.3 Register No. error
DB
0 0 0
39.4
Non-correspondence command
error
DB
3A
Inrush current
suppression circuit
error
3A.1
Inrush current suppression circuit
error
EDB
0 0 0
3E
Operation mode error
3E.1 Operation mode error
DB
3E.6 Operation mode switch error
DB
0 0 0
45
Main circuit device
overheat
45.1 Main circuit device overheat error 1
SD
(Note 1)
(Note 1)
0 1 1
46
Servo motor overheat
46.1
Abnormal temperature of servo
motor 1
SD
(Note 1)
(Note 1)
0 1 1
46.5
Abnormal temperature of servo
motor 3
DB
(Note 1)
(Note 1)
46.6
Abnormal temperature of servo
motor 4
DB
(Note 1)
(Note 1)
47
Cooling fan error
47.2 Cooling fan speed reduction error
SD
0 1 1
50.1
Thermal overload error 1 during
operation
SD
(Note 1)
(Note 1)
50.2
Thermal overload error 2 during
operation
SD
(Note 1)
(Note 1)
50 Overload
1
50.3
Thermal overload error 4 during
operation
SD
(Note 1)
(Note 1)
0 1 1
50.4
Thermal overload error 1 during a
stop
SD
(Note 1)
(Note 1)
50.5
Thermal overload error 2 during a
stop
SD
(Note 1)
(Note 1)
50.6
Thermal overload error 4 during a
stop
SD
(Note 1)
(Note 1)
51 Overload
2
51.1
Thermal overload error 3 during
operation
DB
(Note 1)
(Note 1)
0 1 1
51.2
Thermal overload error 3 during a
stop
DB
(Note 1)
(Note 1)
52.1 Excess droop pulse 1
SD
52 Error
excessive
52.3 Excess droop pulse 2
SD
1 0 1
52.4
Error excessive during 0 torque
limit
SD
52.5 Excess droop pulse 3
EDB
54 Oscillation
detection 54.1
Oscillation detection error
EDB
0 1 1
56
Forced stop error
56.2 Over speed during forced stop
EDB
1 1 0
56.3
Estimated distance over during
forced stop
EDB
61
Operation error
61.1 Point table setting range error
DB
1 0 1
69.1
Forward rotation-side software limit
detection - Command excess error
SD
69 Command
error
69.2
Reverse rotation-side software limit
detection - Command excess error
SD
1 0 1
69.3
Forward rotation stroke end
detection - Command excess error
SD
69.4
Reverse rotation stroke end
detection - Command excess error
SD
86
Network
communication error
86.1 Network communication error 1
SD
86.4 Network communication error 4
SD
0 0 0
86.5 Network communication error 5
SD
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...