7. SPECIAL ADJUSTMENT FUNCTIONS
7 - 7
7.1.3 Shaft resonance suppression filter
POINT
This filter is set properly by default according to servo motor you use and load
moment of inertia. It is recommended that [Pr. PB23] be set to "_ _ _ 0"
(automatic setting) because changing "Shaft resonance suppression filter
selection" in [Pr. PB23] or [Pr. PB17 Shaft resonance suppression filter] may
lower the performance.
(1) Function
When a load is mounted to the servo motor shaft, resonance by shaft torsion during driving may
generate a mechanical vibration at high frequency. The shaft resonance suppression filter suppresses
the vibration.
When you select "Automatic setting", the filter will be set automatically on the basis of the servo motor
you use and the load to motor inertia ratio. The disabled setting increases the response of the servo
amplifier for high resonance frequency.
(2) Parameter
Set "Shaft resonance suppression filter selection" in [Pr. PB23].
[Pr. PB23]
Shaft resonance suppression filter selection
0: Automatic setting
1: Manual setting
2: Disabled
0 1 0
To set [Pr. PB17 Shaft resonance suppression filter] automatically, select "Automatic setting".
To set [Pr. PB17 Shaft resonance suppression filter] manually, select "Manual setting". The setting
values are as follows.
Shaft resonance suppression filter setting frequency selection
Setting value
Frequency [Hz]
Setting value
Frequency [Hz]
_ _ 0 0
Disabled
_ _ 1 0
562
_ _ 0 1
Disabled
_ _ 1 1
529
_ _ 0 2
4500
_ _ 1 2
500
_ _ 0 3
3000
_ _ 1 3
473
_ _ 0 4
2250
_ _ 1 4
450
_ _ 0 5
1800
_ _ 1 5
428
_ _ 0 6
1500
_ _ 1 6
409
_ _ 0 7
1285
_ _ 1 7
391
_ _ 0 8
1125
_ _ 1 8
375
_ _ 0 9
1000
_ _ 1 9
360
_ _ 0 A
900
_ _ 1 A
346
_ _ 0 B
818
_ _ 1 B
333
_ _ 0 C
750
_ _ 1 C
321
_ _ 0 D
692
_ _ 1 D
310
_ _ 0 E
642
_ _ 1 E
300
_ _ 0 F
600
_ _ 1 F
290
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...