4. STARTUP
4 - 30
(a) Control modes and I/O signals
Connector
Pin No.
Signal
input/output
(Note 1) I/O
(Note 2) Symbols of I/O signals in control modes
Related parameter
P P/S S S/T T T/P
CN1
10
I
PP
PP/-
(Note 4)
(Note 4)
(Note 4)
-/PP
PD43/PD44
(Note 3)
15
I
SON SON SON SON SON SON PD03/PD04
16
17
18
19 I RES
RES/ST1
ST1
ST1/RS2
RS2
RS2/RES
PD11/PD12
22
23
O
ZSP ZSP ZSP ZSP ZSP ZSP
PD24
24 O INP
INP/SA
SA
SA/- -/INP PD25
25
33 O OP OP OP OP OP OP
35
I
NP
NP/-
(Note 4)
(Note 4)
(Note 4)
-/NP
PD45/PD46
(Note 3)
37
(Note 6)
I
PP2
PP2/-
(Note 5)
(Note 5)
(Note 5)
-/PP2
PD43/PD44
(Note 3)
38
(Note 6)
I
NP2
NP2/-
(Note 5)
(Note 5)
(Note 5)
-/NP2
PD45/PD46
(Note 3)
41 I CR
CR/ST2
ST2
ST2/RS1
RS1
RS1/CR
PD13/PD14
42
I
EM2 EM2 EM2 EM2 EM2 EM2
43
I
LSP LSP LSP LSP/- -/LSP PD17/PD18
44
I
LSN LSN LSN LSN/- -/LSN PD19/PD20
45
48
O
ALM ALM ALM ALM ALM ALM
49 O RD RD RD RD RD RD
PD28
Note 1. I: input signal, O: output signal
2. P: position control mode, S: speed control mode, T: torque control mode
P/S: position/speed control switching mode, S/T: speed/torque control switching mode, T/P: torque/position switching mode
3 This is available with servo amplifiers with software version B7 or later.
4. This is available as an input device of sink interface. Input devices are not assigned by default. Assign the input devices with
[Pr. PD43] to [Pr. PD46] as necessary. In addition, of 24 DC V to the CN1-12 pin. This is available with servo
amplifiers with software version B7 or later.
5. This is available as an input device of source interface. Input devices are not assigned by default. Assign the input devices
with [Pr. PD43] to [Pr. PD46] as necessary.
6. These pins are available with servo amplifiers having software version B7 or later, and manufactured in May 2015 or later.
(b) Symbol and signal names
Symbol Signal
name Symbol Signal
name
SON Servo-on
RES Reset
LSP
Forward rotation stroke end
EM2
Forced stop 2
LSN
Reverse rotation stroke end
LOP
Control switching
CR Clear
TLC Limiting
torque
SP1
Speed selection 1
VLC
Limiting speed
SP2
Speed selection 2
RD
Ready
PC
Proportion control
ZSP
Zero speed detection
ST1
Forward rotation start
INP
In-position
ST2
Reverse rotation start
SA
Speed reached
RS1
Forward rotation selection
ALM
Malfunction
RS2
Reverse rotation selection
OP
Encoder Z-phase pulse (open collector)
TL
External torque limit selection
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...