5. PARAMETERS
5 - 4
5.1.3 Extension setting parameters ([Pr. PC_ _ ])
No.
Symbol
Name
Initial
value
Unit
Control mode
P S T
PC01
STA
Acceleration time constant
0
[ms]
PC02
STB
Deceleration time constant
0
[ms]
PC03
STC
S-pattern acceleration/deceleration time constant
0
[ms]
PC04
TQC
Torque command time constant
0
[ms]
PC05
SC1
Internal speed command 1
100
[r/min]
Internal speed limit 1
PC06
SC2
Internal speed command 2
500
[r/min]
Internal speed limit 2
PC07
SC3
Internal speed command 3
1000
[r/min]
Internal speed limit 3
PC08
SC4
Internal speed command 4
200
[r/min]
Internal speed limit 4
PC09
SC5
Internal speed command 5
300
[r/min]
Internal speed limit 5
PC10
SC6
Internal speed command 6
500
[r/min]
Internal speed limit 6
PC11
SC7
Internal speed command 7
800
[r/min]
Internal speed limit 7
PC12
VCM
Analog speed command - Maximum speed
0
[r/min]
Analog speed limit - Maximum speed
PC13
TLC
Analog torque command maximum output
100.0
[%]
PC14
MOD1 Analog monitor 1 output
0000h
PC15
MOD2 Analog monitor 2 output
0001h
PC16
MBR
Electromagnetic brake sequence output
0
[ms]
PC17
ZSP
Zero speed
50
[r/min]
PC18
*BPS
Alarm history clear
0000h
PC19
*ENRS Encoder output pulse selection
0000h
PC20
*SNO
Station number setting (Note)
0
[Station]
PC21
*SOP
RS-422 communication function selection (Note)
0000h
PC22
*COP1 Function selection C-1
0020h
PC23
*COP2 Function selection C-2
0000h
PC24
*COP3 Function selection C-3
0000h
PC25
For manufacturer setting
0000h
PC26
*COP5 Function selection C-5
0000h
PC27
*COP6 Function selection C-6
0000h
PC28
For manufacturer setting
0000h
PC29
0000h
PC30
STA2
Acceleration time constant 2
0
[ms]
PC31
STB2
Deceleration time constant 2
0
[ms]
PC32
CMX2 Command input pulse multiplication numerator 2
1
PC33
CMX3 Command input pulse multiplication numerator 3
1
PC34
CMX4 Command input pulse multiplication numerator 4
1
PC35
TL2
Internal torque limit 2
100.0
[%]
PC36
*DMD Status display selection
0000h
PC37
VCO
Analog speed command offset
0
[mV]
Analog speed limit offset
PC38
TPO
Analog torque command offset
0
[mV]
Analog torque limit offset
PC39
MO1
Analog monitor 1 offset
0
[mV]
PC40
MO2
Analog monitor 2 offset
0
[mV]
PC41
For manufacturer setting
0
PC42
0
PC43
ERZ
Error excessive alarm level
0
[rev]
Note. This parameter is supported by servo amplifier manufactured in December 2013 or later.
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...