5. PARAMETERS
5 - 15
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control mode
P S T
PA19
*BLK
Parameter
writing inhibit
Select a reference range and writing range of the parameter.
Refer to table 5.4 for settings.
00AAh
Table 5.4 [Pr. PA19] setting value and reading/writing range
PA19
Setting
operation
PA
PB
PC
PD
PE
PF
Other
than
below
Reading
Writing
000Ah
Reading Only 19
Writing Only 19
000Bh
Reading
Writing
000Ch
Reading
Writing
00AAh
(initial
value)
Reading
Writing
100Bh
Reading
Writing Only 19
100Ch
Reading
Writing Only 19
10AAh
Reading
Writing Only 19
PA20
*TDS
Tough drive
setting
Alarms may not be avoided with the tough drive function depending on the situations of the power supply and load
fluctuation.
You can assign MTTR (During tough drive) to pins CN1-23, CN1-24, and CN1-49 with [Pr. PD24], [Pr. PD25], and [Pr.
PD28].
_ _ _ x For manufacturer setting
0h
_ _ x _ Vibration tough drive selection
0: Disabled
1: Enabled
Selecting "1" enables to suppress vibrations by automatically changing setting
values of [Pr. PB13 Machine resonance suppression filter 1] and [Pr. PB15 Machine
resonance suppression filter 2] in case that the vibration exceed the value of the
oscillation level set in [Pr. PF23].
To output the oscillation detection alarm as a warning, set [Pr. PF24 Vibration tough
drive function selection].
Refer to section 7.3 for details.
0h
_ x _ _ Instantaneous power failure tough drive selection
0: Disabled
1: Enabled
Selecting "1" enables to avoid occurring [AL. 10 Undervoltage] using the electrical
energy charged in the capacitor in the servo amplifier in case that an instantaneous
power failure occurs during operation. In [Pr. PF25 Instantaneous power failure
tough drive - Detection time], set the time until the occurrence of [AL. 10.1 Voltage
drop in the power].
When the digit is enabled, the power should be off for the setting value of [Pr. PF25]
+ 1 s or more before cycling the power to enable a parameter whose symbol is
preceded by "*".
0h
x _ _ _ For manufacturer setting
0h
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...