5. PARAMETERS
5 - 35
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control mode
P S T
PC26
*COP5
Function
selection C-5
_ _ _ x [AL. 99 Stroke limit warning] selection
Enable or disable [AL. 99 Stroke limit warning].
0: Enabled
1: Disabled
0h
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PC27
*COP6
Function
selection C-6
_ _ _ x For manufacturer setting
0h
_ _ x _
0h
_ x _ _ Undervoltage alarm selection
Select the alarm and warning that occurs when the bus voltage drops to the
undervoltage alarm level.
0: [AL. 102] regardless of servo motor speed
1: [AL. E9.1] occurs when the servo motor speed is 50 r/min or less, and [AL. 10.2]
occurs when the servo motor speed is over 50 r/min.
0h
x _ _ _ For manufacturer setting
0h
PC30
STA2
Acceleration
time constant
2
To enable the parameter, turn on STAB2 (Speed acceleration/deceleration
selection).
Set the acceleration time required to reach the rated speed from 0 r/min in response
to VC (Analog speed command) and [Pr. PC05 Internal speed command 1] to [Pr.
PC11 Internal speed command 7].
Setting range: 0 to 50000
0
[ms]
PC31
STB2
Deceleration
time constant
2
To enable the parameter, turn on STAB2 (Speed acceleration/deceleration
selection).
Set the deceleration time required to reach 0 r/min from the rated speed in response
to VC (Analog speed command) and [Pr. PC05 Internal speed command 1] to [Pr.
PC11 Internal speed command 7].
Setting range: 0 to 50000
0
[ms]
PC32
CMX2
Commanded
pulse
multiplication
numerator 2
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic gear
selection" in [Pr. PA21].
Setting range: 1 to 16777215
1
PC33
CMX3
Commanded
pulse
multiplication
numerator 3
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic gear
selection" in [Pr. PA21].
Setting range: 1 to 16777215
1
PC34
CMX4
Commanded
pulse
multiplication
numerator 4
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic gear
selection" in [Pr. PA21].
Setting range: 1 to 16777215
1
PC35
TL2
Internal
torque limit 2
Set the parameter on the assumption that the maximum torque is 100 %. The
parameter is for limiting the torque of the servo motor.
No torque is generated when this parameter is set to "0.0".
When TL1 (Internal torque limit selection) is turned on, Internal torque limits 1 and 2
are compared and the lower value will be enabled.
Set the parameter referring to section 3.6.1 (5).
Setting range: 0.0 to 100.0
100.0
[%]
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...