5. PARAMETERS
5 - 37
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control mode
P S T
PC37
VCO
Analog speed
command
offset/Analog
speed limit
offset
Set the offset voltage of VC (Analog speed command).
For example, if CCW rotation is provided by switching on ST1 (Forward rotation
start) with applying 0 V to VC, set a negative value.
When automatic VC offset is used, the automatically offset value is set to this
parameter. (Refer to section 4.5.4.)
The initial value is provided before shipment by the automatic VC offset function on
condition that the voltage between VC and LG is 0 V.
Setting range: -9999 to 9999
The value
differs
depending
on the
servo
amplifiers.
[mV]
Set the offset voltage of VLA (Analog speed limit).
For example, if CCW rotation is provided by switching on RS1 (Forward rotation
selection) with applying 0 V to VLA, set a negative value.
When automatic VC offset is used, the automatically offset value is set to this
parameter. (Refer to section 4.5.4.)
The initial value is provided before shipment by the automatic VC offset function on
condition that the voltage between VLA and LG is 0 V.
Setting range: -9999 to 9999
PC38
TPO
Analog torque
command
offset/Analog
torque limit
offset
Set the offset voltage of TC (Analog torque command).
Setting range: -9999 to 9999
0
[mV]
Set the offset voltage of TLA (Analog torque limit).
Setting range: -9999 to 9999
PC39
MO1
Analog
monitor 1
offset
Set the offset voltage of MO1 (Analog monitor 1).
Setting range: -9999 to 9999
0
[mV]
PC40
MO2
Analog
monitor 2
offset
Set the offset voltage of MO2 (Analog monitor 2).
Setting range: -9999 to 9999
0
[mV]
PC43
ERZ
Error
excessive
alarm level
Set an error excessive alarm level.
You can change the setting unit with "Error excessive alarm/error excessive warning
level unit selection" in [Pr. PC24].
However, setting "0" will be 3 rev. Setting over 200 rev will be clamped with 200 rev.
Setting range: 0 to 1000
0
[rev]
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...