11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 25
(c) Cable clamp fitting AERSBAN-_SET
Generally, connecting the grounding of the shielded wire to the SD terminal of the connector
provides a sufficient effect. However, the effect can be increased when the shielded wire is
connected directly to the grounding plate as shown below.
Install the grounding plate near the servo amplifier for the encoder cable. Peel part of the cable
sheath to expose the external conductor, and press that part against the grounding plate with the
cable clamp. If the cable is thin, clamp several cables in a bunch.
The cable clamp comes as a set with the grounding plate.
[Unit: mm]
Cable clamp
(A, B)
Cable
Grounding plate
External conductor
Clamp section diagram
40
Strip the cable sheath of
the clamped area.
cutter
cable
Dimensions
[Unit: mm]
Grounding plate
(Note) M4 screw
11
3
6
C
A
6
22
17.5
35
35
7
24
0 -0.
2
B ± 0.3
2-
φ
5 hole
installation hole
[Unit: mm]
Clamp section diagram
L or less
10
30
24
+ 0.
3
0
Note. Screw hole for grounding. Connect it to the grounding plate of the cabinet.
Model A
B
C
Accessory
fittings Clamp
fitting L
AERSBAN-DSET
100
86
30
Clamp A: 2 pcs.
A
70
AERSBAN-ESET
70
56
Clamp B: 1 pc.
B
45
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...