11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 21
(2) Dimensions
4-d mounting hole
(Varnish is removed from front right mounting
hole (face and back side).) (Note 1)
Terminal layout
R X
Z
S Y T
Max. W (Note 2)
W1
D1
D2
H
D or less
Fig. 11.1
Servo amplifier
Power factor
improving AC
reactor
Dimensions
Dimensions [mm]
Terminal
size
Mass
[kg]
W W1 H
D
(Note 3)
D1 D2 d
MR-JE-10A, MR-JE-20A
FR-HAL-0.4K
Fig. 11.1
104 84 99 72 51 40
M5 M4 0.6
MR-JE-40A
FR-HAL-0.75K
104 84 99 74 56 44
M5 M4 0.8
MR-JE-70A
FR-HAL-1.5K
104 84 99 77 61 50
M5 M4 1.1
MR-JE-100A
(3-phase power supply input)
FR-HAL-2.2K
115
(Note 3)
40 115 77 71 57 M6 M4 1.5
MR-JE-100A
(1-phase power supply input)
MR-JE-200A
(3-phase power supply input)
FR-HAL-3.7K
115
(Note 3)
40 115 83 81 67 M6 M4 2.2
MR-JE-200A
(1-phase power supply input)
MR-JE-300A
FR-HAL-5.5K
115
(Note 3)
40 115 83 81 67 M6 M4 2.3
Note 1. Use this for grounding.
2. W ± 2 is applicable for FR-HAL-0.4K to FR-HAL-1.5K.
3.
Maximum
dimensions.
The dimension varies depending on the input/output lines.
11.8 Relay (recommended)
The following relays should be used with the interfaces.
Interface Selection
example
Digital input (interface DI-1)
Relay used for digital input command signals
To prevent defective contacts, use a relay for
small signal (twin contacts).
(Ex.) Omron: type G2A, type MY
Digital output (interface DO-1)
Relay used for digital output signals
Small relay with 12 V DC or 24 V DC of rated
current 40 mA or less
(Ex.) Omron: type MY
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...