5. PARAMETERS
5 - 30
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control mode
P S T
PC03
STC
S-pattern
acceleration/
deceleration
time constant
Start/stop the servo motor smoothly.
Set the time of the arc part for S-pattern acceleration/deceleration.
Setting "0" will make it linear acceleration/deceleration.
Speed command
Se
rv
o m
ot
or
speed
0 r/min
STA
STC
Time
STC
STB
STC
STC
STA: Acceleration time constant ([Pr. PC01])
STB: Deceleration time constant ([Pr. PC02])
STC: S-pattern acceleration/deceleration time constant ([Pr. PC03])
Long setting of STA (acceleration time constant) or STB (deceleration time constant)
may produce an error in the time of the arc part for the setting of the S-pattern
acceleration/deceleration time constant.
The upper limit value of the actual arc part time is limited by
2000000
STA
for acceleration or by
2000000
STB
for deceleration.
(Example) At the setting of STA 20000, STB 5000 and STC 200, the actual arc part
times are as follows.
Acceleration: 100 ms
2000000
20000
= 100 [ms] < 200 [ms]
Therefore, it will be limited to 100 ms.
Deceleration: 200 ms
2000000
5000
= 400 [ms] > 200 [ms]
Therefore, it will be 200 ms as you set.
Setting range: 0 to 5000
0
[ms]
PC04
TQC
Torque
command
time constant
Set the constant of a primary delay to the torque command.
TQC
TQC
Time
Torque
Torque command
After filtering
TQC: Torque command time constant
Setting range: 0 to 50000
0
[ms]
Содержание MR-JE-_A
Страница 9: ...A 8 MEMO ...
Страница 15: ...6 MEMO ...
Страница 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 139: ...4 STARTUP 4 38 MEMO ...
Страница 187: ...5 PARAMETERS 5 48 MEMO ...
Страница 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Страница 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 264: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 265: ...9 DIMENSIONS 9 6 MEMO ...
Страница 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...