8. Spindle Parameters
8.4 MDS-C1-SPM
II - 293
No. Items
Details
Setting
range
Standard
setting
3390 SP190
PG3S Spindle
synchronous
Position loop
gain 3
Set the third position loop gain when high-gain
control is carried out in the spindle
synchronous mode.
When this parameter function is not used, set
to "0".
0 to 999
(1/s)
0
3391
SP191
Use not possible.
0
0
3392
SP192
Not used. Set to "0".
3393
(PR)
SP193 SPECT Synchronized
tapping
specifications
Set the synchronized tapping specifications in
bit units.
0000 to
FFFF
HEX
setting
0000
F E D
C
B A 9 8
zrtn
ptyp od8x
phos
7 6 5 4 3 2 1 0
fdir
cdir
pyfx
rtrn
fclx
bit Name Meaning when set to 0 Meaning when set to 1
0
fclx
Closed loop
Semi-closed loop
(Gear 1 : 1 only)
1
2
rtrn
Position monitor during
ready OFF invalid
Position monitor during
ready OFF valid
3
4
cdir
Command polarity (+)
Command polarity (–)
5
fdir
Position detector
polarity (+)
Position detector
polarity (–)
6
7
8
phos
Normal
(no compensation)
Synchronized tapping
position command
compensation
(for synchronization with
high-gain servo)
9
A
B
C
D
od8x
Magnification of
excessive error width ×
8 times invalid
Magnification of
excessive error width ×
8 times valid
E
ptyp
Position control switch
type: After zero point
return
Position control switch
type: After deceleration
stop
F
zrtn
Zero point return
direction: CCW
Zero point return
direction: CW
Содержание MELDAS 60 Series