5. Base Specifications Parameters
II - 60
#
Items
Details
Setting range (unit)
1225 aux09
(bit0)
PLC Interface
Diagnosis
screen
changeover
Set this to change to the PLC Interface Diagnosis
screen.
0: 40-character compatible screen
1: 80-character compatible screen
0/1
aux09
(bit7)
Enable/disable
spindle
rotation speed
clamp
Specify whether to enable spindle rotation speed
clamp by the spindle rotation speed clamp command
(G92S, Q) instead of the spindle rotation speed
command (R108) specified by the user ladder.
0: Enable
1: Disable
0/1
1226 aux10
(bit0)
Tool compen-
sation data for
external
workpiece
coordinate
offset
measurement
Select the tool offset data to be used for external
workpiece coordinate offset measurement.
0: Tool length data and tool nose wear data
1: Tool length data
0/1
aux10
(bit1)
Optional block
skip type
Specify whether to enable optional block skipping in
the middle of a block.
0: Enable block skipping only at the beginning of a
block.
1: Enable block skipping at the beginning of the
block and in the middle of a block.
0/1
aux10
(bit2)
Single block
stop timing
Specify the time at which the single block signal is
activated.
0: When the signal goes ON while automatic
operation is starting, the block stops after it is
finished.
1: When the signal is ON at the end of the block,
the block stops.
0/1
aux10
(bit3)
C-axis
reference point
return type
Specify the C-axis reference point return type.
0: Origin return is performed by the G28 reference
point return command or when manual
reference point return is activated.
The origin dog is used.
1: When the first C-axis command is issued after
the C-axis mode is entered in automatic mode,
reference point return is performed before
execution of the block. Also, reference return is
performed by the G28 reference point return
command or when manual reference point
return is activated.
The Z phase of the encoder is used.
0/1
aux10
(bit4)
S command
during constant
surface speed
Specify whether to output a strobe signal when the S
command is issued in constant surface speed mode.
0: Output no strobe signal in constant surface
speed mode.
1: Output strobe signals in constant surface speed
mode.
0/1