1. List of Alarms
1.1 Operation Alarms
I - 2
Error No.
Details
Remedy
0006
H/W STRK END (H/W stroke end)
The stroke end function has activated
(the input signal is "OFF") and one of the
axes is in the stroke end status.
• Move the machine manually.
• Check for broken wires in the stroke end
signal wire.
• Check for trouble in the limit switch.
0007
S/W STRK END (S/W stroke end)
The stored stroke limit I‚ II‚ IIB or IB
function has activated.
• Move it manually.
• If the stored stroke limit in the parameter
is incorrectly set‚ correct it.
0008
Chuck/tail-stock barrier stroke end axis
found
The chuck/tail-stock barrier function
turned ON‚ and an axis entered the
stroke end state.
• Reset the alarm with reset‚ and move
the machine in the reverse direction.
0009
Reference point return number illegal
Return to the No. 2 reference point was
performed before return to the No. 1
reference point was completed.
• Execute No. 1 reference point return.
0019
Sensor signal illegal ON
The sensor signal was already ON when
the tool measurement mode (TLM)
signal was validated.
The sensor signal turned ON when there
was no axis movement after the tool
measurement mode (TLM) signal was
validated.
The sensor signal turned ON at a
position within 100
μ
m from the final
entry start position.
• Turn the tool measurement mode signal
input OFF, and move the axis in a safe
direction.
• The operation alarm will turn OFF even
when the sensor signal is turned OFF.
Note)
When the tool measurement mode
signal input is turned OFF, the axis
can be moved in either direction.
Pay attention to the movement
direction.
0020
Reference point return illegal
Return to the reference point was
performed before the coordinates had
not been established.
• Execute reference point return
0024
Zero point return disabled during absolute
position detection alarm
A zero point return signal was input
during an absolute position detection
alarm.
• Reset the absolute position detection
alarm‚ and then perform zero point
return.
0025
Zero point return disabled during zero
point initialization
A zero point return signal was input
during zero point initialization of the
absolute position detection system.
• Complete zero point initialization‚ and
then perform zero point return.
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......