7. Servo Parameters
7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
II - 153
No. Items
Details
Setting
range
2235 SV035
SSF4
Servo
function
selection 4
F E D C B A 9 8
clt clG1 cl2n
clet
cltq
7 6 5 4 3 2 1 0
ckab iup
tdt
bit
Meaning when "0" is set
Meaning when "1" is set
0
1
2
3
4
5
tdt
Td creation time setting
Set to “0”. (For machine tool builder adjustment)
6 iup
Set to "1" when using any of motors from HC152 to HC702 and
from HC153 to HC453.
7 ckab
Setting for normal use
No signal 2 (Alarm 21) special
detection
8
Set the retracting torque for collision detection in respect to the
maximum torque of the motor.
9
cltq
00: 100%
01: 90%
10: 80% (Standard)
11: 70%
A clet Setting for normal use
The disturbance torque peak of
the latest two seconds is
displayed in MPOS of the servo
monitor screen.
B cl2n
Collision detection method 2
valid
Collision detection method 2
invalid
C
D
E
clG1
Collision detection method 1
Set the collision detection level during cutting feed (G1).
The G1 collision detection level=SV060*clG1.
When clG1=0, the collision detection method 1 during cutting
feed won't function.
F clt Setting for normal use
The guide value of the SV059
setting value is displayed in
MPOS of the servo monitor
screen.
(Note) bit7 (ckab) is only for MDS-C1-Vx.
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......