8. Spindle Parameters
8.2 MDS-B-SPJ2
II - 219
No. Items
Details
Setting
range
Standard
setting
3235
(PR)
SP035 SFNC3 Spindle
function3
Set the spindle function 3 in bit units.
0000 to
FFFF
HEX setting
0000
3236
(PR)
SP036 SFNC4
Spindle
function 4
Set the spindle function 4 in bit units.
F E D
C
B A 9 8
dslm dssm
7 6 5 4 3 2 1 0
enc2 enc1 mag2 mag1 plg2 plg1
(Note)
Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
plg1
PLG of motor 1 valid
PLG of motor 1 invalid
1
plg2
PLG of motor 2 valid
PLG of motor 2 invalid
2
mag1
MAG of motor 1 valid
MAG of motor 1 invalid
3
mag2
MAG of motor 2 valid
MAG of motor 2 invalid
4
enc1
ENC of motor 1 valid
ENC of motor 1 invalid
5
enc2
ENC of motor 2 valid
ENC of motor 2 invalid
6
7
8
dssm
Speedometer valid
Speedometer invalid
9
dslm
Load meter valid
Load meter invalid
A
B
C
D
E
F
(Note)
Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
hwid
H-coil wide-range
constant output invalid
H-coil wide-range
constant output valid
1
2
hbsd
H-coil base slide invalid
H-coil base slide valid
3
4
5
6
7
8
9
A
B
C
D
E
F
F E D
C
B A 9 8
7 6 5 4 3 2 1 0
hbsd
hwid