5. Base Specifications Parameters
II - 54
#
Items
Details
Setting range (unit)
1214 macaxy
(For L
system
only)
Side 2 of
inclination
angle
Specify the length of the actual base axis
corresponding to the inclined axis in the triangle
made up of the inclination angle.
±9999.999
1215 macaxx
(For L
system
only)
Side 3 of
inclination
angle
Specify the length of the actual axis of the inclined
axis in the triangle made up of the inclination angle.
±9999.999
1216 extdcc
External
deceleration
level
Use an upper limit value at the feedrate indicated
when validating external deceleration signals.
This parameter is valid when #1239 set11/bit6 is set
to 0.
1 to 999999 (mm/min)