8. Spindle Parameters
8.4 MDS-C1-SPM
II - 301
No. Items
Details
Setting
range
Standard
setting
3521
(PR)
to
3584
(PR)
SP321
to
SP384
RPML
BSDL
Motor
constant
(L coil)
This parameter is valid only in the
following conditional case:
(a) In case that SP034 (SFNC2) bit0=1
and SP034 (SFNC2) bit2=1
Set the motor constant of the L coil of
the coil changeover motor.
(Note)
It is not allowed for the user to
change the setting.
0000 to
FFFF
HEX setting
0000
<Details for Motor constant>
No. Items
Details
Setting
range
Standard
setting
3558 SP358 KtL
Torque
constant 2
for
disturbance
observer
Set the torque constant for disturbance
observer.
30-minute
rated output
× 1000
Setting
(0.01kg•m)=
Base speed × 1.026
× 100
0000 to
FFFF
HEX setting
-
3559 SP359 GDML
Motor
inertia 2 for
disturbance
observer
Set the motor inertia for disturbance
observer.
Setting (0.001kg•m
2
)=GD
M
2
× 1000
0000 to
FFFF
HEX setting
-
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......