6. Axis Specifications Parameters
6.1 Axis Specifications Parameters
II - 94
#
Items
Details
Setting range (unit)
2004 G0tL
G0 time constant
(linear)
Set up a linear control time constant for rapid traverse
acceleration and deceleration.
The time constant is validated when LR (rapid
traverse feed with linear acceleration or deceleration)
or F (acceleration or deceleration by software) is
selected in acceleration or deceleration mode "#2003
smgst".
G0tL
Speed
G0tL
Time
1 to 4000 (ms)
2005 G0t1
G0 time constant
(primary delay)
Second-step
time constant for
acceleration and
deceleration by
software
Set up a primary-delay time constant for rapid
traverse acceleration and deceleration.
The time constant is validated when R1 (rapid
traverse feed with primary delay) or R3 (exponential
acceleration and linear deceleration) is selected in
acceleration or deceleration mode "#2003 smgst".
When acceleration or deceleration by software is
selected, the second-step time constant is used.
<Rapid traverse feed with exponential
acceleration and linear deceleration>
G0t1
Speed
2 G0t1
Time
G0t1
Speed
Time
G0t1
<Rapid traverse feed with primary delay>
1 to 5000 (ms)
2006 G0t2
Not used.
0