8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
II - 260
No. Items
Details
Setting
range
Standard
setting
3370
(PR)
SP170
VGUD Speed
loop
gain delay
advance item
for increased
spindle
holding force
Set the speed loop gain delay advance item
for when the disturbance observer is valid.
0 to 5000
(0.1 1/s)
15
3371
to
3376
SP171
to
SP176
Not used. Set to "0".
0
0
3377
(PR)
SP177 SPECS Spindle
synchronous
specifica-
tions
Set the spindle synchronous specifications in
bit units.
0000 to
FFFF
HEX
setting
0000
3378
(PR)
SP178 VGSP
Spindle
synchronous
speed loop
gain propor-
tional term
Set the speed loop proportional gain in spindle
synchronous mode.
0 to 1000
(1/s)
63
3379
(PR)
SP179 VGSI
Spindle
synchronous
speed loop
gain integral
term
Set the speed loop integral gain in spindle
synchronous mode.
0 to 1000
(0.1 1/s)
60
bit Name Meaning when set to 0 Meaning when set to 1
0
fclx
Closed loop
Semi-closed loop
1
adin
Interpolation A/D
compensation invalid
Interpolation A/D
compensation valid
2
rtrn
Position monitor during
ready OFF invalid
Position monitor during
ready OFF valid
3
pyfx
Normal excitation
Position loop excitation
fixed (strong)
4
5
fdir
Position detector direc-
tion (positive direction)
Position detector direc-
tion (negative direction)
6
7
8
9
A
B
C
D
odx8
Magnification of
excessive error width ×
8 times invalid
Magnification of
excessive error width ×
8 times valid
E
F
(Used with SPJ)
F E D
C
B A 9 8
Odx8
phos
7 6 5 4 3 2 1 0
fdir
pyfx
rtrn
adin
fclx
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......