12. Position Switch
12.2 Canceling the Position Switch
II - 324
Rotation axis
Setting of dog1 and dog2
dog1, dog2 position
Description
dog1 < dog2
dog2 dog1
(Example)
dog1 =
30.000
dog2 = 330.000
A signal is output
between dog1 and
dog2.
dog1 dog2
(Example)
dog1 = -30.000
dog2 =
30.000
A signal is also output
when dog1 is negative.
dog1 > dog2
dog1 dog2
(Example)
dog1 = 330.000
dog2 =
30.000
A signal is output
between dog2 and
dog1.
⏐
dog1 - dog2
⏐
≥
360
dog2 dog1
(Example)
dog1 =
30.000
dog2 = 390.000
A signal is kept output
when the difference
between dog1 and dog2
exceeds 360 degrees.
12.2 Canceling the Position Switch
To cancel the position switch‚ enter the number (#75 1) of the position switch to be canceled in # ( ) of the
setting field‚ enter a slash "/" in DATA ( )‚ then press the INPUT key. This deletes the axis name for the
specified position switch‚ thus invalidating the position switch.
The data specified for <dog1> and <dog2> are still stored in memory. To validate the position switch again‚
therefore‚ it is enough to specify the axis name only.
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......