6. Axis Specifications Parameters
6.2 Zero Point Return Parameters
II - 100
#
Items
Details
Setting range (unit)
2030
(PR)
dir (-)
Reference
point direction
(-)
Set which side of the near-point dog the reference
point is at during reference point return.
<For dog type reference point return>
Negative
direction
Positive
direction
dir(-)=0
dir(-)=1
Near-point dog
Direction in which zero point is established
as viewed from the near-point dog
0: Positive direction
1: Negative direction
2031 noref
Axis without
reference point
Specify the axis that does not have a reference point.
Before automatic operation starts, reference point
return is not required.
0: Normal controlled
axis
1: Axis without
reference point
2032 nochk
Whether
reference point
return is
completed not
checked
The absolute and incremental commands can be
executed even if dog type (or Z phase pulse system)
reference point return is not completed.
Specify whether to check that the reference point
return is completed.
0: Reference point
return completion
is checked.
1: Reference point
return completion
is not checked.
2033 zp_no
Z phase pulse
system
reference point
return spindle
encoder No.
The reference point return is performed with the Z
phase pulse of the spindle encoder. Set the spindle
encoder No. to be used.
0: Dog type
1 to 4: Spindle No.
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......