6. Axis Specifications Parameters
6.3 Absolute Position Parameters
II - 103
#
Items
Details
Setting range (unit)
2057 nrefp
Near zero
point +
Set the width where the near-reference-point signal is
output. (Positive direction width)
When set to 0‚ the width is equivalent to the grid width
setting.
Note: When #1240 set12 (bit2) is ON, a magnification
(C: 10-fold, D: 100-fold) corresponding to the
input setting unit (#1003 iunit) will be applied on
the setting value.
0 to 32.767 (mm)
2058 nrefn
Near zero
point -
Set the width where the near-reference-point signal is
output. (Negative direction width)
When set to 0‚ the width is equivalent to the grid width
setting.
Note: When #1240 set12 (bit2) is ON, a magnification
(C: 10-fold, D: 100-fold) corresponding to the
input setting unit (#1003 iunit) will be applied on
the setting value.
0 to 32.767 (mm)
2059 zerbas Select zero
point
parameter
and reference
point
Specify the position to be the zero point coordinate
during absolute position initial setting.
0: Position that was stopped during stopper
method
Specify the coordinates of the alignment mark
position when using the reference point
method.
1: Grid point just before stopper
Specify the coordinates of the grid point just
before the alignment mark.
0/1
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......