5. Base Specifications Parameters
II - 46
#
Items
Details
Setting range (unit)
1154
(PR)
pdoor Door
interlock
II (for each
system)
Specify whether to control door interlock II
independently for each of the two systems. When door
interlock II is controlled for each system of the two
systems, system 1 is connected to SV1 (channel 1) of
the base I/O unit and system 2 is connected to SV2
(channel 2) of the base I/O unit.
Base I/O unit
SV1
SV2
AMP
AMP
AMP
System 1
AMP
AMP
AMP
System 2
When the auxiliary axis (MR-J2-CT) is used, connect it
to the SV2 side (after the spindle). This validates door
interlock II of system 2.
0: Do not use door interlock II independently for
channels.
1: Use door interlock II independently for channels.
(Separate systems when using two systems)
2: Use door interlock II independently for channels.
(Use independently for system 1 channels)
(Use both for system 2)
When 0 is specified for this parameter, “Signal input
device 1 for door interlock II (#1155 DOOR_m)” and
“Signal input device 2 for door interlock II (#1156
DOOR_s)” are valid. When 1 is specified, “Signal input
device 1 for door interlock II: for each system (#1511
DOORPm)” and “Signal input device 2 for door interlock
II: for each system (#1512 DOORPs)”.
0/1