8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
II - 244
No. Items
Details
Setting
range
Standard
setting
3240
(PR)
SP040 MTYP Motor type
This parameter is valid when SP034 (SFNC2)
bit0 is set to "0".
Set the appropriate motor number from the
standard motors listed below.
0000 to
FFFF
HEX
setting
0000
Parameter
setting
Motor type
Maximum
speed
Corre-spo
nding
amplifier
0000
0001 SJ-2.2A 10000
r/min
SP-22
0002 SJ-3.7A 10000
r/min
SP-37
0003 SJ-5.5A
8000
r/min
SP-55
0004 SJ-7.5A
8000
r/min
SP-75
0005 SJ-11A
6000
r/min
SP-110
0006 SJ-15A
6000
r/min
SP-150
0007 SJ-18.5A 6000
r/min
SP-185
0008 SJ-22A
4500
r/min
SP-220
0009 SJ-26A
4500
r/min
SP-260
000A SJ-30A
4500
r/min
SP-300
000B
000C
000D
000E
000F
0010
0011 SJ-N0.75A
10000
r/min
SP-075
0012 SJ-N1.5A 10000
r/min
SP-15
0013 SJ-N2.2A 10000
r/min
SP-22
0014 SJ-N3.7A 10000
r/min
SP-37
0015 SJ-N5.5A 8000
r/min
SP-55
0016 SJ-N7.5A 8000
r/min
SP-75
0017
0018
0019
001A
001B SJ-J2.2A 10000
r/min
SP-22
001C SJ-J3.7A 10000
r/min
SP-37
001D SJ-J5.5A 8000
r/min
SP-55
001E SJ-J7.5A 8000
r/min
SP-75
001F
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......