8. Spindle Parameters
8.2 MDS-B-SPJ2
II - 224
No. Items
Details
Setting
range
Standard
setting
3267
(PR)
SP067 VIGWA Change starting
speed of variable
current loop gain
Set the speed for starting change of current
loop gain.
0 to
32767
(r/min)
0
3268
(PR)
SP068 VIGWB Change ending
speed of variable
current loop gain
Set the speed for ending change of current
loop gain.
0 to
32767
(r/min)
0
3269
(PR)
SP069 VIGN
Target value of
variable current
loop gain
Set the magnification of current loop gain
(torque component and excitation
component) for a change ending speed
defined in SP068 (VIGWB).
When this parameter is set to "0", the
magnification is 1.
SP067
SP017
SP068
Speed
Gain
SP069×(1/16)-fold
1-fold
SP017 (TSP)
Maximum
motor speed
SP067
(VIGWA)
SP068
(VIGWB)
SP069
(VIGN)
0
to
6000
0 0 0
6001 to 8000
5000
8000
45
8001 or more
5000
10000
64
0 to
32767
(1/16
-fold)
0
3270
SP070
Not used. Set to "0".
0 0
3271
(PR)
SP071 VR2WA
3272
(PR)
SP072 VR2WB
3273
(PR)
SP073 VR2GN
3274
(PR)
SP074 IGDEC
3275
SP075 R2KWS
Fixed control
constant
Set by Mitsubishi.
Set "0" unless designated in particular.
0 0
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......