7. Servo Parameters
7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
II - 146
No. Items
Details
Setting
range
Set the excessive error detection width when servo ON.
<Standard setting value>
Rapid traverse rate
(mm/min)
OD1=OD2=
60*PGN1
/2 (mm)
2223 SV023
OD1
Excessive
error
detection
width during
servo ON
When "0" is set, the excessive error detection will not be
performed.
0 to 32767
(mm)
2224 SV024
INP
In-position
detection
width
Set the in-position detection width.
Set the accuracy required for the machine.
The lower the setting is, the higher the positioning
accuracy gets, however, the cycle time (setting time)
becomes longer. The standard setting is “50”.
0 to 32767
(µm)
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......