8. Spindle Parameters
8.2 MDS-B-SPJ2
II - 227
No. Items
Details
Setting
range
Standard
setting
3301
(PR)
SP101 DINP
Orientation
advance
in-position
width
When using the orientation in-position
advance function, set the in-position width
that is larger than the normal in-position
width defined in SP004 (OINP).
1 to 2880
(1/16°)
16
3302
(PR)
SP102 OODR Excessive
error value in
orientation
mode
Set the excessive error width in orientation
mode.
1 to 32767
(1/4 pulse)
(1 pulse=
0.088°)
32767
3303
(PR)
SP103 FTM
Index
positioning
completion
OFF time timer
Set the time for forcedly turn OFF the index
positioning completion signal (different from
the orientation completion signal) after the
leading edge of the indexing start signal.
1 to 10000
(ms)
200
3304
(PR)
SP104 TLOR Torque limit
value for
orientation
servo locking
Set the torque limit value for orientation
in-position output.
If the external torque limit signal is input the
torque limit value set by this parameter is
made invalid.
1 to 120
(%)
100
3305
(PR)
SP105 IQG0
Current loop
gain magnifica-
tion 1 in
orientation
mode
Set the magnification for current loop gain
(torque component) at orientation
completion.
1 to 1000
(%)
100
3306 SP106
IDG0 Current
loop
gain magnifica-
tion 2 in
orientation
mode
Set the magnification for current loop gain
(excitation component) at orientation
completion.
1 to 1000
(%)
100
3307 SP107
CSP2 Deceleration
rate 2 in
orientation
mode
Set the deceleration rate in orientation mode
corresponding to the gear 001.
When this parameter is set to "0", same as
SP006 (CSP).
0 to 1000
0
3308 SP108
CSP3 Deceleration
rate 3 in
orientation
mode
Set the deceleration rate in orientation mode
corresponding to the gear 010.
When this parameter is set to "0", same as
SP006 (CSP).
0 to 1000
0
3309
(PR)
SP109 CSP4 Deceleration
rate 4 in
orientation
mode
Set the deceleration rate in orientation mode
corresponding to the gear 011.
When this parameter is set to "0", same as
SP006 (CSP).
0 to 1000
0
3310
(PR)
SP110 WCML Turret index
command
magnifica-
tion
The integer magnification (gear ratio 1 : N)
for the index position command (0 to 359) is
set.
0 to 32767
(fold)
0
3311 SP111
WDEL Turret
index
deceleration
magnifica-
tion
The magnification for the orientation
deceleration rate is set using 256 as 1.
0 to 32767
(1/256
-fold)
0
3312 SP112
WCLP Turret
index
clamp speed
The max. speed during indexing is set. This
becomes the max. speed of the motor when
set to "0".
0 to 32767
(r/min)
0