5. Base Specifications Parameters
II - 88
#
Items
Details
Setting range (unit)
1555 Iv0rd3
Involute
interpolation
override 3
Set the override value at the curvature radius Iv0vR3
for executing involute interpolation with the
high-speed high-accuracy II mode.
Note: If the override value is not set (setting value:
0), the setting will be invalid, and the override
will be 100%.
1 to 100 (%)
1556 Iv0rd4
Involute
interpolation
override 4
Set the override value at the curvature radius Iv0vR4
for executing involute interpolation with the
high-speed high-accuracy II mode.
Note: If the override value is not set (setting value:
0), the setting will be invalid, and the override
will be 100%.
1 to 100 (%)
1557 Iv0rd5
Involute
interpolation
override 5
Set the override value at the curvature radius Iv0vR5
for executing involute interpolation with the
high-speed high-accuracy II mode.
Note: If the override value is not set (setting value:
0), the setting will be invalid, and the override
will be 100%.
1 to 100 (%)
1558 Iv0Min
Involute
interpolation
override lower
limit value
Set the lower limit value of the involute interpolation
override.
Note: If the override value is not set (setting value:
0), the setting will be invalid, and the override
will be 100%.
1 to 100 (%)
1559 IvAMax Involute
interpolation
maximum
acceleration
rate
Set the maximum acceleration rate of the constant
acceleration control for executing involute
interpolation with the high-speed high-accuracy II
mode.
Note: If this parameter is not set (setting value: 0),
the setting will be invalid, and the normal
acceleration rate (#1207 G1btL) will be
applied.
1 to 32767 (ms)
1560 IvFMin
Involute
interpolation
minimum
feedrate
Set the minimum feedrate of the constant
acceleration control for executing involute
interpolation with the high-speed high-accuracy II
mode. (Valid when executing compensation with the
accuracy coefficient.)
Note: If this parameter is not set (setting value: 0),
the feedrate will not be clamped.
1 to 32767 (ms)
1571 SSSdis SSS control
adjustment
coefficient
fixed value
selection
The shape recognition range for SSS control is
fixed.
0/1
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......