2. Machining Parameters
2.3 Axis Parameters
II - 12
2.3 Axis Parameters
Set up the parameter required for each axis.
#
Item
Contents
Setup range (unit)
8201 AX. RELEASE
Select the function to remove the control axis from
the control target.
0: Control as normal.
1: Remove from control target.
0/1
8202 OT-CHECK OFF
Select the stored stroke limit II function set in #8204
and #8205.
0: Stored stroke limit II valid
1: Stored stroke limit II invalid
0/1
8203 OT-CHECK-CANCEL
When the simple absolute position method (#2049
type is 9) is selected‚ the stored stroke limits I, II (or
IIB) and IB will be invalid until the first zero point
return is executed after the power is turned ON.
0: Stored stroke limit II valid (according to
#8202)
1: Stored stroke limit II invalid
Note: Temporary cancel of #8203 soft limit affects
all the stored stroke limits.
0/1
8204 OT-CHECK-N
This sets the coordinates of the (-) direction in the
moveable range of the stored stroke limit II or the
lower limit coordinates of the prohibited range of
stored stroke limit IIB.
If the sign and value are the same as #8205, the
stored stroke limit II (or IIB) will be invalid.
If the stored stroke limit IIB function is selected, the
prohibited range will be between two points even
when #8204 and #8205 are set in reverse.
When II is selected, the entire range will be
prohibited.
±99999.999 (mm)
8205 OT-CHECK-P
This sets the coordinates of the (+) direction in the
moveable range of the stored stroke limit II or the
upper limit coordinates of the prohibited range of
stored stroke limit IIB.
±99999.999 (mm)
8206 TOOL CHG. P
Set the coordinates of the tool change position for
G30. n (tool change position return).
Set with coordinates in the basic machine
coordinate system.
±99999.999 (mm)
8207 G76/87 IGNR
(For M system only)
Select the shift operation at G76 (fine boring) and
G87 (back boring).
0: Shift effective
1: No shift
8208 G76/87 (–)
(For M system only)
Specifies the shift direction at G76 and G87.
0: Shift to (+) direction
1: Shift to (-) direction
8209 G60 SHIFT
(For M system only)
Set the last positioning direction and distance for a
G60 (uni-directional positioning) command.
±99999.999 (mm)