Items
Details
Setting range (unit)
1050
(PR)
MemPrg Definition
of
program save
area
Setting
0 1 2 3
Machining program
MDI data
(Machining program)
: System common
Machining program save area is shared by
systems.
: System independent
Machining programs can be registered for
each system.
(MDI data)
: System common
MDI data is shared by systems.
: System independent
MDI data can be set for each system.
When this parameter is changed, the power must
be turned OFF and ON, and the system formatted.
(Note) This parameter is valid when #1001
SYS_ON[2] is 1.
0 to 3
1051
(PR)
MemTol Tool
compensa-
tion memory
common for
systems
0: Tool compensation memory separate for
systems
1: Tool compensation memory common for
systems
0/1
1052
(PR)
MemVal No.
of
common
variables
shared in
system
designation
0: Common variables common for system
(number fixed)
#100 to : Per system
#500 to : Common for systems
1: Common variables common for system
(number fixed)
#100 to : Designate with V1comN
#500 to : Designate with V0comN
* When this parameter is changed, the method of
reading the file system will change after the power
is turned ON, so always reformat again.
Setting order
MemVal
change-
over
Format
Mismatch
displays
Format
Turn
power ON
again
0/1