8. Spindle Parameters
8.2 MDS-B-SPJ2
II - 228
No. Items
Details
Setting
range
Standard
setting
3313
(PR)
SP113 WINP
Turret index
in-position
width
The position error range is set in which an
orientation (indexing) completed signal is
output during turret indexing. This
becomes the same as SP004 (OINP)
when set to "0".
0 to 32767
(1/16°)
0
3314 SP114
OPER Orientation
pulse miss
check value
An alarm "5C" will occur if the pulse miss
value in the orientation stop exceed this
setting value. (Note that this is invalid
when set to "0".)
In this parameter, set the value to fulfill the
following conditions.
SP114 setting value > 1.5 × SP004
(orientation in-position width)
0 to 32767
(360°/4096)
0
3315 SP115
OSP2 Orientation
changeover
speed limit
value 2
When the door interlock spindle speed
clamp signal is ON, this setting is used
instead of OSP(SP005), CZRN(SP149)
and TZRN(SP214). (Note that SP149 and
SP214 are used only for the M65V.)
0 to 32767
(r/min)
0
3316
SP116 OPYVR
3317
SP117 ORUT
Fixed control
constants
Set by Mitsubishi.
Set "0" unless designated in particular.
0 0
3318 SP118
ORCT Number
of
orientation
retry times
Set the number of times to retry when an
orientation or feedback error occurs.
The warning (A9) is issued while retrying
orientation, and an alarm (5C) is issued
when the set number of times is
exceeded.
0 to 100
(time)
0
3319
to
3376
SP119
to
SP176
Not used. Set to "0".
0 0
Содержание MELDAS 60 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...I EXPLANATION OF ALARMS ...
Страница 14: ......
Страница 95: ...II EXPLANATION OF PARAMETERS ...
Страница 96: ......
Страница 443: ......