5. Base Specifications Parameters
II - 55
(SETUP PARAM 1. 8/15)
#
Items
Details
Setting range (unit)
1217 aux01
Not used
1218 aux02
(bit3)
Parameter
input/output
format
Specify a parameter input/output format.
0: Type
I
1: Type II (related to #1218 aux02/bit5)
0/1
aux02
(bit4)
Tool number
selection
Specify the R register that contains the tool number
used for automatic calculation when measuring the
coordinate offset of an external workpiece.
0: Conforms to #1130 set_t.
1: Uses the tool number indicated by user PLC
0/1
aux02
(bit5)
Parameter I/O
II spindle
specification
address
Specify the spindle specification address of parameter
I/O type II.
0: C
1: T
This parameter also applies to the spindle specification
address for input and collation.
Note: This parameter is valid only for parameter I/O
type II (bit 3 of aux02 in #1218 is 1).
0/1
aux02
(bit6)
Set No. valid
when
program input
Specify which program No. is selected when inputting
operation using "#1 MAIN PROGRAM" in Data I/O
screen.
0: The No. in the input data is valid.
1: The No. set in the data setting area is valid.
0/1
aux02
(bit7)
Input by
program
overwrite
(1) When inputting operation using "#1 MAIN
PROGRAM" in Data I/O screen, select one of the
following options when the input program has
already been registered:
0: An operation error (E65) occurs.
1: Input by overwrite.
(2) When using the high-speed program server, select
the operation if the name of the file to be transmitted
with transmission (IC
→
host) operations already
exists in the host.
0: Overwrite
prohibit
1: Overwrite
valid
0/1
1219 aux03
(bit1)
Stop high-
speed PC
monitoring
function
Set 1 to disable the function that stops the system when
the high-speed processing time is extended.
Disable the monitoring function only as a temporary
measure.
0/1
aux03
(bit2)
Improve skip
coordinate
accuracy
0: Skip accuracy (conventional specification)
1: Changes skip accuracy (correct a position in skip
coordinates when entering skip signals).
0/1
aux03
(bit5)
Dog-type
intermediate
point
Select whether to move to the intermediate point during
automatic dog-type reference point return.
0: Do not move to intermediate point during
dog-type reference point return.
1: Move to intermediate point during dog-type
reference point return.
0/1