5. Base Specifications Parameters
II - 66
#
Items
Details
Setting range (unit)
set04
(bit0)
Switch load
monitor
Select whether to detect the load with the load
monitor's load detection, excluding during
acceleration/
deceleration.
0: Detect also during acceleration/deceleration.
(Conventional)
1: Do not detect during
acceleration/deceleration.
0/1
1232
set04
(bit1)
Program format
(IC card)
Select the format of the file output during copying
(NC
→
IC).
0: Add “%” to the head of the file.
1: The head of the file is No. 0.
0/1
1233 set05
(bit1)
Spindle clamp
selection
Select whether to validate the spindle override for
the spindle speed clamp command (G92 S?).
0: Spindle override invalid
1: Spindle override valid
0/1
1234 set06
(bit6)
Not
used.
0/1
set06
(bit7)
Enable/disable
MELDASNET
Enable or disable the MELDASNET function.
0: Enable
1: Disable
0/1
1235 set07
(bit0)
Helical
interpolation
speed 2
0: Select normal speed designation also for 3rd
axis
1: Select arc plane element speed designation
0/1
(MAGIC64)
set07
(bit1)
File server
selection for
version upgrade
0: Set upper limit of program file size to 2
gigabytes.
1: Set upper limit of program file size to 16
megabytes.
0/1
(MAGIC64)
set07
(bit2)
Fixed type
chopping
compensa-
tion valid only at
start
When the fixed type compensation value is
selected, the method is changed to the
compensation value sequential update type after
the first four cycles.
0: Method changeover invalid
1: Method changeover valid
0/1
1236 set08
(bit0)
Manual rotation
axis feedrate
unit
Select the unit of manual rotation axis feedrate.
0: Fixed to [°/min]
1: Same speed as before
0/1
set08
(bit1)
Spindle speed
detection
Select the pulse input source of actual spindle
rotation speed output (R18/19) when spindle
encoder serial connection (#3025 enc-on: 2) is
selected.
0: Serial input
1: Encoder input connector
0/1
set08
(bit2)
Current limit
droop cancel
invalid
Set whether to cancel the position droop when the
current limit changeover signal is canceled.
0: Cancel
droop.
1: Do not cancel droop.
0/1
set08
(bit7)
Not
used.
0/1