5-8 Image Optimization
Effects
Images can be optimized with less spot noise and higher resolution, so that more
details for the structure are revealed.
Impacts
iBeam is not valid for phased probes.
Image Merge
Description
In the Dual-split mode, when the images of the two windows have the same probe
type, depth, invert status, rotation status and magnification factor, the system will
merge the two images so as to extend the field of vision.
Operations
Turn the function on or off using the [Auto Merge] item or the mapping-menu item on
the touch screen.
Impacts
The function is valid only for linear probes.
Gray Map
Description
This function applies the gray correction to obtain optimum images.
Operations
Select from among the maps by rotating the knob under the [Gray Map] item or the
mapping-menu item on the touch screen. The system provides 8 different gray effect
maps.
Tint Map
Description
This function provides an imaging process based on color difference rather than gray
distinction.
Operations
Rotate the knob under the [Tint Map] item or the mapping-menu item on the touch
screen to select the map. The system provides 8 different color effect maps.
TSI (Tissue Specific Imaging)
Description
The TSI function is used to optimize the image by selecting acoustic speed according
to tissue characteristics.
Operations
Select from among the TSI modes using the [TSI] item or the mapping-menu item on
the touch screen.
The system provides four ways of optimizing for specific tissues: general, muscle, fluid
and fat.
iTouch (Auto Image Optimization)
Description
To optimize image parameters as per the current tissue characteristics for a better
image effect.
Operations
Press <iTouch> on the control panel to turn the function on.
The iTouch symbol will be displayed in the image parameter area of the screen once
<iTouch> is pressed.
Select different levels of iTouch effect using [iTouch] on the touch screen or the
mapping-menu.
Long press the <iTouch> key to exit the function.
Содержание DC-80A
Страница 2: ......
Страница 24: ......
Страница 44: ......
Страница 58: ...3 14 System Preparation Uninstalling Press the clip in the direction of the arrow to get out the holder...
Страница 59: ...System Preparation 3 15...
Страница 67: ...System Preparation 3 23...
Страница 68: ......
Страница 80: ......
Страница 299: ...Probes and Biopsy 13 19...
Страница 304: ...13 24 Probes and Biopsy NGB 035 NGB 039...
Страница 324: ......
Страница 334: ......
Страница 340: ......
Страница 348: ......
Страница 352: ......
Страница 363: ...Barcode Reader B 11...
Страница 368: ......
Страница 382: ......
Страница 391: ...P N 046 014137 00 3 0...