Manual
LCom
Page 136 of 158
<start>
Program name
The specified program is
started asynchronously, i.e.
processing continues without
waiting for the started program
to end, and without evaluating
any return value.
<kill>
Program name
The specified program is
aborted/killed (if possible).
<runcmd>
Command
The specified command is
processed
in “cmd.exe”.
<firmup>
Device Address, Firmware File, [Verify
ON/OFF]
The specified firmware file
(.mot) is transferred to the
device with the specified
address. There is an option to
switch verification on (ON) (by
re-reading the device data).
(Standard is: verification is
off). Note: verify MUST be off
for Wsx00 compact weather
stations!
<csconf>
Device address,
channel,
active, (0/1 or ON)
[id1, (for TLS -> FG)
id2, (for TLS -> Type)
id3, (for TLS -> Channel)
Name,
Scaling,
str_id1 (reserved)
str_id2 (reserved)
id4, (for TLS: physical channel)
MMSI Id,
MMSI Type,
Value Map ID,
Store active (0/1)
Statistic type
The configuration for the
corresponding sensor channel
is changed. As a minimum,
“device address”, “channel”
and “active” must be set; all
other parameters are optional.
<reset-tls-modem>
The TLS modem is reset by
switching off the GUB3 power
supply.
Содержание 8511.EAK
Страница 1: ...Operating Manual LCom Lufft Communicator Order No 8511 EAK Version V2 18 1 11 2019 www lufft com ...
Страница 41: ...5 8 2 8 essSubSurfaceSensorTable The parameters for the subsurface temperature sensors are configured here ...
Страница 42: ...5 8 2 9 essSnapShotCameraTable The camera s is are configured here See Camera Support below ...
Страница 124: ...Manual LCom Page 124 of 158 The button show events opens a dialog showing the events stored on the device ...
Страница 133: ...Manual LCom Page 133 of 158 reactivated by disconnecting and reconnecting the USB stick wait time 3 seconds ...
Страница 153: ...Manual LCom Page 153 of 158 6 2 Connection Example ...