make the
“individual” directories on the server (which the station creates
automatically) easily assignable (e.g. "SH_WARDER" or "SH_AHRENSBOEK"
etc.).
Note: The ID must be selected so that it is a valid directory name on a
Unix System (FTP server), i.e. no spaces or special characters (the
configuration interface does NOT verify this).
•
Debug Flags
: Settings for debug/trace outputs in the log file.
•
Display Off Timeout
: Time after which the display is switched off (and any
logged on user is logged off).
•
Enable Telnet
: Telnet access is enabled or disabled. User name and
password are required for Telnet access in all cases.
•
Log File Path
: Directory for the log and trace file. Default is \log\ -> on the
RAM drive. It can be changed to a different directory (e.g. \FFSDISK2), if the
log files are to be stored permanently.
Note
: Writing to the NAND flash or USB stick takes a relatively long time and
can influence the timing/response behavior of the Inselbus (TLS protocol)
under certain debug/trace level settings.
•
Device Settings:
parameters for the UMB / Opus device communication (see
below)
•
Wavetronix Click512
: parameters for transmitting Wavetronix Click512
events (see below)
•
Auto Adjust DST:
automatically adjust DST / standard time
•
Timezone:
set the timezone for the LCom clock
•
LCom Language:
language settings for the LCom user interface.
Note:
when changing the language settings, the MSSI sensor type and value
mapping entries can optionally be re-initialized in the new language. Any
changes to the MSSI sensor types or value mapping entries will be lost if this
is selected!
•
Use Data Store
: If the system is equipped with an SD card, data storage on
the SD card can be enabled here. The maximum number of sensor channels
that can be stored depends on the size of the SD card.
Note 1
: The SD card is initialized after enabling this function. This can take a
Содержание 8511.EAK
Страница 1: ...Operating Manual LCom Lufft Communicator Order No 8511 EAK Version V2 18 1 11 2019 www lufft com ...
Страница 41: ...5 8 2 8 essSubSurfaceSensorTable The parameters for the subsurface temperature sensors are configured here ...
Страница 42: ...5 8 2 9 essSnapShotCameraTable The camera s is are configured here See Camera Support below ...
Страница 124: ...Manual LCom Page 124 of 158 The button show events opens a dialog showing the events stored on the device ...
Страница 133: ...Manual LCom Page 133 of 158 reactivated by disconnecting and reconnecting the USB stick wait time 3 seconds ...
Страница 153: ...Manual LCom Page 153 of 158 6 2 Connection Example ...