Manual
LCom
Page 113 of 158
•
Simulation Active:
The simulation model for saline concentration and freeze
temperature is activated
•
Values TLS coded:
the input values (waterfilm) are TLS coded. Note that this
does not affect the coding of the output values
– i.e. the freeze temperature is
always reported as °C and may need to be scaled (for transmission via TLS).
•
Number of Instances:
the number of model calculation instances
•
Instance #:
select the instance to be configured via this combo box
Instance Parameter:
•
Saline Concentration Sensor:
the sensor channel for saline concentration
(road sensor output)
•
Waterfilm Sensor:
the sensor channel for water film height (road sensor
output)
•
RS Factor:
multiplication factor for raw salinity value
•
Waterfilm Limit:
minimal water film for measured salinity
•
Dry Decrease Factor:
reduction divisor (dry road)
•
Decrease Time:
time constant for reduction on wet road