5.13.3 Boschung Alarm Code
Various
parameters for calculating the „Boschung Alarm Code“ can be set here:
Besides the sensor channels for the input values to the model, coding parameters for
these input values can be set as well.
•
The “TLS coded” parameter besides the air temperature channel applies to all
input temperatures, i.e. if set the input temperatures are treated as 1/10 °C
(instead of standard °C)
•
The “TLS coded” parameter besides the road condition channel determines
whether the input road condition is TLS or Lufft encoded.
•
Treat Errors
as “No Alarm”: set result value to 0 (no Alarm) on error conditions
instead of setting error code for result value.
•
“waterfilm wet” sets the waterfilm threshold for “wet” condition
•
Trace Modell: if active, trace messages from the model calculation are written
to the error log
5.13.3.1
Rules for calculating the Boschung Alarm Code (Model Version 1):