![Lufft 8511.EAK Скачать руководство пользователя страница 141](http://html1.mh-extra.com/html/lufft/8511-eak/8511-eak_operating-manual_1947031141.webp)
Manual
LCom
Page 141 of 158
5.20 Service Program
The service program connects to the LCom via TCP/IP; it can be used over both LAN
and Internet (GPRS/CDMA) connections.
Basically the service program is built like the user interface on the LCom (but without
the “RS232 Test” dialog).
After the connection has been established, the clock settings on the LCom are
checked
and synchronized with the PC if necessary. The LCom’s language (country)
setting is also compared with the service program and adjusted if necessary.
The following addit
ional functions are available under the “Edit” menu heading:
•
Update firmware:
The firmware of the active UMB sensors connected to the
LCom can be updated by means of this function. In this case the firmware
(.mot) file is first transferred to the LCom and then imported into the UMB
device.
•
Update LCom software:
The LCom software can be updated.
•
Edit file:
A file is transferred from the LCom and an editor is started. If the file
was changed the modified file is transferred back again.
•
File transfer from LCom:
A file is transferred from the LCom to the PC.
•
File transfer to LCom:
A file is transferred from the PC to the LCom.
•
UMB Direct Access Mode:
a “transparent mode” to access the UMB bus on
the LCom via a local IP port is started. The LCom cannot access the UMB
sensors while the “Direct Access Mode” is active – i.e. the LCom cannot read
out measure values etc. while in direct access mode. If
the “UMB config tool”
is installed on the computer, the UMB config tool is started. Access to the
UMB devices is via TCP/IP on localhost, port 8000 (default, can be configured
via help/options)
Содержание 8511.EAK
Страница 1: ...Operating Manual LCom Lufft Communicator Order No 8511 EAK Version V2 18 1 11 2019 www lufft com ...
Страница 41: ...5 8 2 8 essSubSurfaceSensorTable The parameters for the subsurface temperature sensors are configured here ...
Страница 42: ...5 8 2 9 essSnapShotCameraTable The camera s is are configured here See Camera Support below ...
Страница 124: ...Manual LCom Page 124 of 158 The button show events opens a dialog showing the events stored on the device ...
Страница 133: ...Manual LCom Page 133 of 158 reactivated by disconnecting and reconnecting the USB stick wait time 3 seconds ...
Страница 153: ...Manual LCom Page 153 of 158 6 2 Connection Example ...