Multiple instances for the model calculation can be configured (in case the station is
equipped with more than one road sensor).
Note: the default values are preset for the (German) TLS protocol, e.g. the “Dewpoint
diff” value of 5.0 refers to 0.5 °C as the temperatures for TLS are in 1/10 °C.
Please adjust the parameters as needed for the sensor channels configured here.
•
Active: this instance of the model calculation is active
•
Dewpoint Diff: the value that the road temperature must be below the dew
point temperature for “slippery frosty” to be set (see above)
•
Road Condition Dry: the road condition code for “dry”
•
Slippery Frosty: the road condition code for “slippery frosty”
•
Road Condition: the road condition sensor channel
•
Road Temperature: the road temperature sensor channel
•
Water Film: the water film sensor channel
•
Dew point: the dew point sensor cannel
Содержание 8511.EAK
Страница 1: ...Operating Manual LCom Lufft Communicator Order No 8511 EAK Version V2 18 1 11 2019 www lufft com ...
Страница 41: ...5 8 2 8 essSubSurfaceSensorTable The parameters for the subsurface temperature sensors are configured here ...
Страница 42: ...5 8 2 9 essSnapShotCameraTable The camera s is are configured here See Camera Support below ...
Страница 124: ...Manual LCom Page 124 of 158 The button show events opens a dialog showing the events stored on the device ...
Страница 133: ...Manual LCom Page 133 of 158 reactivated by disconnecting and reconnecting the USB stick wait time 3 seconds ...
Страница 153: ...Manual LCom Page 153 of 158 6 2 Connection Example ...