5.8.3.2.3 sensorData.digitalOutputStatus subtree
this subtree contains a table to show the status of the digital outputs (e.g. used to control traffic signals) configured as
“alarm” outputs.
Configuration and status data is directly derived from the alarm configuration, so no sensor channels are assigned to these OIDs.
digitalOutputStatus.numDigitalOutputPorts.0
.1.3.6.1.4.1.1206.3.50.1.3.1.0
Configurable
-
digitalOutputStatus.digitalOutputStatusTable.digitalOutputStatusEntry.digitalOutputStatusIndex.x
.1.3.6.1.4.1.1206.3.50.1.3.2.1.1.x
-
digitalOutputStatus.digitalOutputStatusTable.digitalOutputStatusEntry.deviceName.x
.1.3.6.1.4.1.1206.3.50.1.3.2.1.2.x
Configurable
-
digitalOutputStatus.digitalOutputStatusTable.digitalOutputStatusEntry.devicePort.x
.1.3.6.1.4.1.1206.3.50.1.3.2.1.3.x
Configurable
digitalOutputStatus.digitalOutputStatusTable.digitalOutputStatusEntry.outputStatus.x
.1.3.6.1.4.1.1206.3.50.1.1.2.1.4.x
calcChannels.numSandStormDetectionEntries
.1.3.6.1.4.1.1206.3.50.1.2.6.0
Configurable
calcChannels.sandStormDetectionTable.sandStormDetectionEntry.sandStormDetectionIndex.x
.1.3.6.1.4.1.1206.3.50.1.2.7.1.1.X
calcChannels.sandStormDetectionTable.sandStormDetectionEntry.sandStormDetectionCode.x
.1.3.6.1.4.1.1206.3.50.1.2.7.1.2.x
Sand Storm Detection
(calculated)
calcChannels.numWetSpotDetectionEntries
.1.3.6.1.4.1.1206.3.50.1.2.8.0
Configurable
calcChannels.wetSpotDetectionTable.wetSpotDetectionEntry.wetSpotDetectionIndex.x
.1.3.6.1.4.1.1206.3.50.1.2.9.1.1.x
calcChannels.wetSpotDetectionTable.wetSpotDetectionEntry.wetSpotDetectionCode.x
.1.3.6.1.4.1.1206.3.50.1.2.9.1.2.x
Wet Spot Detection (calculated)
5.8.3.2.4 sensorData.instrumentation subtree
here the status of UPS, batteries and doors can be monitored.
instrumentation.upsStatus.0
.1.3.6.1.4.1.1206.3.50.1.4.1.0
UPS status.
0 = power OK,
1 = power not OK / battery
operation,
2= error or missing value
instrumentation.upsBatteryStatus.0
.1.3.6.1.4.1.1206.3.50.1.4.2.0
UPS battery status
0 = OK
1 = battery power low
2 = error or missing value
instrumentation.numBatteries.0
.1.3.6.1.4.1.1206.3.50.1.4.3.0
Configurable
-
Содержание 8511.EAK
Страница 1: ...Operating Manual LCom Lufft Communicator Order No 8511 EAK Version V2 18 1 11 2019 www lufft com ...
Страница 41: ...5 8 2 8 essSubSurfaceSensorTable The parameters for the subsurface temperature sensors are configured here ...
Страница 42: ...5 8 2 9 essSnapShotCameraTable The camera s is are configured here See Camera Support below ...
Страница 124: ...Manual LCom Page 124 of 158 The button show events opens a dialog showing the events stored on the device ...
Страница 133: ...Manual LCom Page 133 of 158 reactivated by disconnecting and reconnecting the USB stick wait time 3 seconds ...
Страница 153: ...Manual LCom Page 153 of 158 6 2 Connection Example ...