Type 49: temperature control
Type 50: light
Type 51: (standard) power supply
Type 52: heating
Type 53: ventilation
Type 54: surge protection
Type 55: theft/vandalism
Mapping of the “source” values from the assigned UMB sensor channel to the
appropriate TLS coding for each type may have to be done by configuring an
appropriate value mapping for the sensor.
Exception: “extended power supply” (type 151): no value mapping (even if configured
for the UMB sensor channel) is applied, but the “source” value is processed using the
special rules for this user defined TLS type.
For door contact (type 48) channels, the input value (after processed by a configured
value mapping if appropriate) is always negated (i.e. a value != 0 is treated as “door
closed”, a value == 0 as “door open”).
Furthermore, multiple channels of the same DE type are now supported for TLS FG6.
Note regarding the MSSI sensor configuration:
The MSSI protocol (see below) for the transmission of measured data and camera
images is supported from LCom Version 1.3.0. The MSSI protocol can be
enabled/configured in addition to
an alternative “uplink protocol” (such as TLS), or as
the only protocol (if no other uplink protocol is active).
A sensor channel that has a “MSSI Sensor ID” and a MSSI sensor type assigned (i.e.
id != 0 and type != 0) is “presented” via MSSI, i.e. the sensor status and the measure
value are transmitted.
For most sensor channels, the MSSI sensor type and the MSSI sensor id will be
assigned automatically.
Содержание 8511.EAK
Страница 1: ...Operating Manual LCom Lufft Communicator Order No 8511 EAK Version V2 18 1 11 2019 www lufft com ...
Страница 41: ...5 8 2 8 essSubSurfaceSensorTable The parameters for the subsurface temperature sensors are configured here ...
Страница 42: ...5 8 2 9 essSnapShotCameraTable The camera s is are configured here See Camera Support below ...
Страница 124: ...Manual LCom Page 124 of 158 The button show events opens a dialog showing the events stored on the device ...
Страница 133: ...Manual LCom Page 133 of 158 reactivated by disconnecting and reconnecting the USB stick wait time 3 seconds ...
Страница 153: ...Manual LCom Page 153 of 158 6 2 Connection Example ...