5.13.15
Wet Spot Detection
The input values for wet spot detection are
•
Waterfilm
•
Precipitation Intensity
•
Air Temperature
•
Relative Humidity
A simulated water film value is calculated from these input measurements. If the
measured value for water film level
– multiplied by the configured waterfilm compare
factor
– is above the simulated (=expected) water film level, a “wet spot” is detected.
Result:
0: no wet spot detected
1: wet spot detected