![Lufft 8511.EAK Скачать руководство пользователя страница 119](http://html1.mh-extra.com/html/lufft/8511-eak/8511-eak_operating-manual_1947031119.webp)
Manual
LCom
Page 119 of 158
•
Road Condition:
the road condition sensor channel
•
Precipitation Type:
the precipitation type sensor channel
•
Friction:
the friction sensor channel
•
Air Temp. Threshold:
the air temperature threshold value (default 0)
•
Road Temp
. Threshold: the road temperature threshold value (default 0)
•
Road Condition Encoding:
encoding/type of the road condition sensor
channel
•
Precipitation Type Encoding:
encoding/type of the precipitation sensor
channel
•
Friction threshold:
the friction threshold (default 0.4)
A result value of 0 indicates no alarm condition, i.e. the beacon should be switched
off
A result value greater than 0 indicates an alarm condition, i.e. the beacon should be
switched on. The different alarm values (1…5) indicate which of the alarm conditions
shown in the following flow chart was met.
Содержание 8511.EAK
Страница 1: ...Operating Manual LCom Lufft Communicator Order No 8511 EAK Version V2 18 1 11 2019 www lufft com ...
Страница 41: ...5 8 2 8 essSubSurfaceSensorTable The parameters for the subsurface temperature sensors are configured here ...
Страница 42: ...5 8 2 9 essSnapShotCameraTable The camera s is are configured here See Camera Support below ...
Страница 124: ...Manual LCom Page 124 of 158 The button show events opens a dialog showing the events stored on the device ...
Страница 133: ...Manual LCom Page 133 of 158 reactivated by disconnecting and reconnecting the USB stick wait time 3 seconds ...
Страница 153: ...Manual LCom Page 153 of 158 6 2 Connection Example ...