5.8.2.12.2
historySensorOidTable
Here, the OIDs for the NTCIP data store are configured.
On the left side, all OIDs that have a sensor assignment (i.e. should report measure
values) and that have not been configured for the data store are listed. On the right
side the OIDs already configured for the data store are shown.
For each OID that is configured for data storage, a “statistics type” can be configured.
This statistics type is used to calculate an aggregated value for the reporting interval
when retrieving data from the data store, if the reporting interval is greater than the
actual store interval (which is fixed to 1 minute).